http://hl7.org/fhir/StructureDefinition/oxygensat|5.0.0
FHIR Oxygen Saturation Profile
{
"description": "FHIR Oxygen Saturation Profile",
"package": "hl7.fhir.r5.core@5.0.0",
"date": "2018-10-23T00:00:00Z",
"derivation": "constraint",
"publisher": "Health Level Seven International (Orders and Observations Workgroup)",
"fhirVersion": "5.0.0",
"name": "Observationoxygensat",
"mapping": [ {
"uri": "http://hl7.org/fhir/workflow",
"name": "Workflow Pattern",
"identity": "workflow"
}, {
"uri": "http://snomed.info/conceptdomain",
"name": "SNOMED CT Concept Domain Binding",
"identity": "sct-concept"
}, {
"uri": "http://hl7.org/v2",
"name": "HL7 V2 Mapping",
"identity": "v2"
}, {
"uri": "http://hl7.org/v3",
"name": "RIM Mapping",
"identity": "rim"
}, {
"uri": "http://hl7.org/fhir/fivews",
"name": "FiveWs Pattern Mapping",
"identity": "w5"
}, {
"uri": "http://snomed.org/attributebinding",
"name": "SNOMED CT Attribute Binding",
"identity": "sct-attr"
} ],
"abstract": false,
"type": "Observation",
"experimental": false,
"resourceType": "StructureDefinition",
"fhirversion": null,
"title": "Observation Oxygen Saturation Profile",
"versionAlgorithmCoding": null,
"extension": [ {
"url": "http://hl7.org/fhir/StructureDefinition/structuredefinition-summary",
"valueMarkdown": "\"#### Complete Summary of the Mandatory Requirements\n\n1. One code in `Observation.code` which must have\n - a fixed `Observation.code.coding.system`=**'http ://loinc.org'**\n - a fixed `Observation.code.coding.code`= **'2708-6'**\n - Other additional Codings are allowed in `Observation.code`- e.g. more specific LOINC\n Codes, SNOMED CT concepts, system specific codes. All codes\n SHALL have a system value\n1. Either one Observation.valueQuantity or, if there is no value, one code in Observation.DataAbsentReason\n - Each Observation.valueQuantity must have:\n - One numeric value in Observation.valueQuantity.value\n - a fixed Observation.valueQuantity.system=\"http://unitsofmeasure.org\"\n - a UCUM unit code in Observation.valueQuantity.code = **'%'**"
}, {
"url": "http://hl7.org/fhir/StructureDefinition/structuredefinition-fmm",
"valueInteger": 5
}, {
"url": "http://hl7.org/fhir/StructureDefinition/structuredefinition-wg",
"valueCode": "oo"
}, {
"url": "http://hl7.org/fhir/StructureDefinition/structuredefinition-standards-status",
"valueCode": "trial-use"
}, {
"url": "http://hl7.org/fhir/tools/StructureDefinition/profile-summary",
"valueString": "\"#### Complete Summary of the Mandatory Requirements\n\n1. One code in `Observation.code` which must have\n - a fixed `Observation.code.coding.system`=**'http ://loinc.org'**\n - a fixed `Observation.code.coding.code`= **'2708-6'**\n - Other additional Codings are allowed in `Observation.code`- e.g. more specific LOINC\n Codes, SNOMED CT concepts, system specific codes. All codes\n SHALL have a system value\n1. Either one Observation.valueQuantity or, if there is no value, one code in Observation.DataAbsentReason\n - Each Observation.valueQuantity must have:\n - One numeric value in Observation.valueQuantity.value\n - a fixed Observation.valueQuantity.system=\"http://unitsofmeasure.org\"\n - a UCUM unit code in Observation.valueQuantity.code = **'%'**"
} ],
"status": "draft",
"id": "c272bef1-247f-574b-b4e2-c958b2d6abb2",
"kind": "resource",
"url": "http://hl7.org/fhir/StructureDefinition/oxygensat",
"identifier": [ {
"value": "urn:oid:2.16.840.1.113883.4.642.5.1457",
"system": "urn:ietf:rfc:3986"
} ],
"versionAlgorithmString": null,
"fhir_id": null,
"version": "5.0.0",
"contact": [ {
"telecom": [ {
"value": "http://www.hl7.org/Special/committees/orders/index.cfm Orders and Observations",
"system": "url"
} ]
} ],
"baseDefinition": "http://hl7.org/fhir/StructureDefinition/vitalsigns"
}