http://hl7.org/fhir/StructureDefinition/vitalsigns|5.0.0

FHIR Vital Signs Profile
{
  "description": "FHIR Vital Signs Profile",
  "package": "hl7.fhir.r5.core@5.0.0",
  "date": "2016-03-25T00:00:00Z",
  "derivation": "constraint",
  "publisher": "Health Level Seven International (Orders and Observations Workgroup)",
  "fhirVersion": "5.0.0",
  "name": "Observationvitalsigns",
  "mapping": [ {
    "uri": "http://hl7.org/fhir/workflow",
    "name": "Workflow Pattern",
    "identity": "workflow"
  }, {
    "uri": "http://snomed.info/conceptdomain",
    "name": "SNOMED CT Concept Domain Binding",
    "identity": "sct-concept"
  }, {
    "uri": "http://hl7.org/v2",
    "name": "HL7 V2 Mapping",
    "identity": "v2"
  }, {
    "uri": "http://hl7.org/v3",
    "name": "RIM Mapping",
    "identity": "rim"
  }, {
    "uri": "http://hl7.org/fhir/fivews",
    "name": "FiveWs Pattern Mapping",
    "identity": "w5"
  }, {
    "uri": "http://snomed.org/attributebinding",
    "name": "SNOMED CT Attribute Binding",
    "identity": "sct-attr"
  } ],
  "abstract": false,
  "type": "Observation",
  "experimental": false,
  "resourceType": "StructureDefinition",
  "fhirversion": null,
  "title": "Vital Signs Profile",
  "versionAlgorithmCoding": null,
  "extension": [ {
    "url": "http://hl7.org/fhir/StructureDefinition/structuredefinition-summary",
    "valueMarkdown": "\"#### Complete Summary of the Mandatory Requirements\n\n1.  One status in `Observation.status` which has a [required](terminologies.html#extensible) binding to:\n    -    [ObservationStatus] value set.\n1.  A category in `Observation.category` which must have:\n    -   a fixed `Observation.category.coding.system`=\"http://terminology.hl7.org/CodeSystem/observation-category\"\n    -   a fixed `Observation.category.coding.code`= \"vital-signs\"\n\n1.  A code in `Observation.code`\n    -   a fixed `Observation.code.coding.system`= \"http://loinc.org\"\"\n    -   a LOINC code in `Observation.code.coding.code` which has an [extensible](terminologies.html#extensible) binding to:\n         -   [Vital Signs] value set.\n                \n1.  One patient in `Observation.subject`\n1.  A date and time in `effectiveDateTime` or `effectivePeriod`\n1.  Either one `Observation.value[x]` or, if there is no value, one code in `Observation.DataAbsentReason`\n    -   if a vital sign measure then:\n        -  One numeric value in Observation.valueQuantity.value\n        - a fixed Observation.valueQuantity.system=\"http://unitsofmeasure.org\"\n        - a UCUM unit code in Observation.valueQuantity.code which has a required binding to the [Vital Signs Units] value set.\n    -   Observation.DataAbsentReason is bound to [Observation Value\n        Absent Reason] value set.\n\n1.  When using a panel code to group component observations (Note: See\n    the comments regarding blood pressure in the table above), one or\n    more `Observation.component.code` each of which must have:\n    -   a fixed\n        `Observation.component.code.coding.system` =\"\"http://loinc.org\"\"\n         -   a LOINC code in `Observation.code.coding.code` which has an [extensible] binding to:\n             -   [Vital Signs Units] value set.\n\n1.  Either one `Observation.component.valueQuantity` or, if there is\n    no value, one code in `Observation.component.DataAbsentReason`\n    -   Observation.component.DataAbsentReason is bound to [Observation\n        Value Absent Reason] value set.\n\n1.  When using a panel code to group observations, one or more reference\n    to Vitals Signs Observations in `Observation.related.target`\n    -   a fixed `Observation.related.type`= \"has-member\"\"\n\n [Vital Signs]: valueset-observation-vitalsignresult.html\n  [Vital Signs Units]: valueset-ucum-vitals-common.html\n  [extensible]: terminologies.html#extensible\n  [ObservationStatus]: valueset-observation-status.html\n [Observation Value Absent Reason]: valueset-data-absent-reason.html\n[required]: terminologies.html#required\""
  }, {
    "url": "http://hl7.org/fhir/StructureDefinition/structuredefinition-fmm",
    "valueInteger": 5
  }, {
    "url": "http://hl7.org/fhir/StructureDefinition/structuredefinition-wg",
    "valueCode": "oo"
  }, {
    "url": "http://hl7.org/fhir/StructureDefinition/structuredefinition-standards-status",
    "valueCode": "trial-use"
  }, {
    "url": "http://hl7.org/fhir/tools/StructureDefinition/profile-summary",
    "valueString": "\"#### Complete Summary of the Mandatory Requirements\n\n1.  One status in `Observation.status` which has a [required](terminologies.html#extensible) binding to:\n    -    [ObservationStatus] value set.\n1.  A category in `Observation.category` which must have:\n    -   a fixed `Observation.category.coding.system`=\"http://terminology.hl7.org/CodeSystem/observation-category\"\n    -   a fixed `Observation.category.coding.code`= \"vital-signs\"\n\n1.  A code in `Observation.code`\n    -   a fixed `Observation.code.coding.system`= \"http://loinc.org\"\"\n    -   a LOINC code in `Observation.code.coding.code` which has an [extensible](terminologies.html#extensible) binding to:\n         -   [Vital Signs] value set.\n                \n1.  One patient in `Observation.subject`\n1.  A date and time in `effectiveDateTime` or `effectivePeriod`\n1.  Either one `Observation.value[x]` or, if there is no value, one code in `Observation.DataAbsentReason`\n    -   if a vital sign measure then:\n        -  One numeric value in Observation.valueQuantity.value\n        - a fixed Observation.valueQuantity.system=\"http://unitsofmeasure.org\"\n        - a UCUM unit code in Observation.valueQuantity.code which has a required binding to the [Vital Signs Units] value set.\n    -   Observation.DataAbsentReason is bound to [Observation Value\n        Absent Reason] value set.\n\n1.  When using a panel code to group component observations (Note: See\n    the comments regarding blood pressure in the table above), one or\n    more `Observation.component.code` each of which must have:\n    -   a fixed\n        `Observation.component.code.coding.system` =\"\"http://loinc.org\"\"\n         -   a LOINC code in `Observation.code.coding.code` which has an [extensible] binding to:\n             -   [Vital Signs Units] value set.\n\n1.  Either one `Observation.component.valueQuantity` or, if there is\n    no value, one code in `Observation.component.DataAbsentReason`\n    -   Observation.component.DataAbsentReason is bound to [Observation\n        Value Absent Reason] value set.\n\n1.  When using a panel code to group observations, one or more reference\n    to Vitals Signs Observations in `Observation.related.target`\n    -   a fixed `Observation.related.type`= \"has-member\"\"\n\n [Vital Signs]: valueset-observation-vitalsignresult.html\n  [Vital Signs Units]: valueset-ucum-vitals-common.html\n  [extensible]: terminologies.html#extensible\n  [ObservationStatus]: valueset-observation-status.html\n [Observation Value Absent Reason]: valueset-data-absent-reason.html\n[required]: terminologies.html#required\""
  } ],
  "status": "draft",
  "id": "88a399f4-b64a-5ba9-8cee-e769b898a07a",
  "kind": "resource",
  "url": "http://hl7.org/fhir/StructureDefinition/vitalsigns",
  "identifier": [ {
    "value": "urn:oid:2.16.840.1.113883.4.642.5.1461",
    "system": "urn:ietf:rfc:3986"
  } ],
  "versionAlgorithmString": null,
  "fhir_id": null,
  "version": "5.0.0",
  "contact": [ {
    "telecom": [ {
      "value": "http://www.hl7.org/Special/committees/orders/index.cfm Orders and Observations",
      "system": "url"
    } ]
  } ],
  "baseDefinition": "http://hl7.org/fhir/StructureDefinition/Observation"
}