http://hl7.org/fhir/StructureDefinition/Device|4.0.1
A type of a manufactured item that is used in the provision of healthcare without being substantially changed through that activity. The device may be a medical or non-medical device.
| Name | Flags | Card | Type | Description & Constraints |
|---|---|---|---|---|
Device | 0..* | Item used in healthcare | ||
| 0..* | Identifier | Instance identifier | ||
| 0..1 | Reference | The reference to the definition for the device | ||
Σ | 0..* | BackboneElement | Unique Device Identifier (UDI) Barcode string | |
Σ | 0..1 | string | Mandatory fixed portion of UDI | |
| 0..1 | uri | UDI Issuing Organization | ||
| 0..1 | uri | Regional UDI authority | ||
Σ | 0..1 | base64Binary | UDI Machine Readable Barcode String | |
Σ | 0..1 | string | UDI Human Readable Barcode String | |
| 0..1 | code | barcode | rfid | manual + UDIEntryType (required) | ||
?!Σ | 0..1 | code | active | inactive | entered-in-error | unknown FHIRDeviceStatus (required) | |
| 0..* | CodeableConcept | online | paused | standby | offline | not-ready | transduc-discon | hw-discon | off FHIRDeviceStatusReason (extensible) | ||
| 0..1 | string | The distinct identification string | ||
| 0..1 | string | Name of device manufacturer | ||
| 0..1 | dateTime | Date when the device was made | ||
| 0..1 | dateTime | Date and time of expiry of this device (if applicable) | ||
| 0..1 | string | Lot number of manufacture | ||
| 0..1 | string | Serial number assigned by the manufacturer | ||
| 0..* | BackboneElement | The name of the device as given by the manufacturer | ||
| 1..1 | string | The name of the device | ||
| 1..1 | code | udi-label-name | user-friendly-name | patient-reported-name | manufacturer-name | model-name | other DeviceNameType (required) | ||
| 0..1 | string | The model number for the device | ||
| 0..1 | string | The part number of the device | ||
| 0..1 | CodeableConcept | The kind or type of device DeviceType (example) | ||
| 0..* | BackboneElement | The capabilities supported on a device, the standards to which the device conforms for a particular purpose, and used for the communication | ||
| 1..1 | CodeableConcept | The standard that is used to operate and communicate | ||
| 0..1 | string | The version of the standard that is used to operate and communicate | ||
| 0..* | BackboneElement | The actual design of the device or software version running on the device | ||
| 0..1 | CodeableConcept | The type of the device version | ||
| 0..1 | Identifier | A single component of the device version | ||
| 1..1 | string | The version text | ||
| 0..* | BackboneElement | The actual configuration settings of a device as it actually operates, e.g., regulation status, time properties | ||
| 1..1 | CodeableConcept | Code that specifies the property DeviceDefinitionPropetyCode (Extensible) | ||
| 0..* | Quantity | Property value as a quantity | ||
| 0..* | CodeableConcept | Property value as a code, e.g., NTP4 (synced to NTP) | ||
| 0..1 | Reference | Patient to whom Device is affixed | ||
| 0..1 | Reference | Organization responsible for device | ||
| 0..* | ContactPoint | Details for human/organization for support | ||
| 0..1 | Reference | Where the device is found | ||
| 0..1 | uri | Network address to contact device | ||
| 0..* | Annotation | Device notes and comments | ||
Σ | 0..* | CodeableConcept | Safety Characteristics of Device | |
| 0..1 | Reference | The parent device |