http://terminology.hl7.org/CodeSystem/v3-ObservationInterpretation|3.0.0

name
ObservationInterpretation
package
hl7.terminology.r5@6.3.0
content
complete
status
active
date
2019-03-20 00:00:00.0

ObservationInterpretation

One or more codes providing a rough qualitative interpretation of the observation, such as \"normal\" / \"abnormal\", \"low\" / \"high\", \"better\" / \"worse\", \"resistant\" / \"susceptible\", \"expected\" / \"not expected\". The value set is intended to be for ANY use where coded representation of an interpretation is needed.

codedisplaydefinitionhierarchy
_ObservationInterpretationChangeObservationInterpretationChange
Interpretations of change of quantity and/or severity. At most one of B or W and one of U or D allow...
_GeneticObservationInterpretationGeneticObservationInterpretation
Codes that specify interpretation of genetic analysis, such as \"positive\", \"negative\", \"carrier...
_ObservationInterpretationExceptionsObservationInterpretationExceptions
Technical exceptions resulting in the inability to provide an interpretation. At most one allowed. D...
_ObservationInterpretationNormalityObservationInterpretationNormality
Interpretation of normality or degree of abnormality (including critical or \"alert\" level). Concep...
_ObservationInterpretationSusceptibilityObservationInterpretationSusceptibility
Interpretations of anti-microbial susceptibility testing results (microbiology). At most one allowed...
EXoutside threshold
The observation/test result is interpreted as being outside the inclusion range for a particular pro...
HMHold for Medical Review
Hold for Medical Review\r\n\r\n*Usage Note:* This code is not intended for use in V3 artifacts. It i...
ObservationInterpretationDetectionObservationInterpretationDetection
Interpretations of the presence or absence of a component / analyte or organism in a test or of a si...
ObservationInterpretationExpectationObservationInterpretationExpectation
Interpretation of the observed result taking into account additional information (contraindicators) ...
OBXInterpretation qualifiers in separate OBX segments
Interpretation qualifiers in separate OBX segments\r\n\r\n*Usage Note:* This code is not intended fo...
ReactivityObservationInterpretationReactivityObservationInterpretation
Interpretations of the presence and level of reactivity of the specified component / analyte with th...
CARCarrier
The patient is considered as carrier based on the testing results. A carrier is an individual who ca...
CarrierCarrier
The patient is considered as carrier based on the testing results. A carrier is an individual who ca...
BBetter
The current result or observation value has improved compared to the previous result or observation ...
DSignificant change down
The current result has decreased from the previous result for a quantitative observation (the change...
USignificant change up
The current result has increased from the previous result for a quantitative observation (the change...
WWorse
The current result or observation value has degraded compared to the previous result or observation ...
<Off scale low
The result is below the minimum detection limit (the test procedure or equipment is the limiting fac...
>Off scale high
The result is above the maximum quantifiable limit (the test procedure or equipment is the limiting ...
ACAnti-complementary substances present
A valid result cannot be obtained for the specified component / analyte due to the presence of anti-...
IEInsufficient evidence
There is insufficient evidence that the species in question is a good target for therapy with the dr...
QCFQuality control failure
A result cannot be considered valid for the specified component / analyte or organism due to failure...
TOXCytotoxic substance present
A valid result cannot be obtained for the specified organism or cell line due to the presence of cyt...
AAbnormal
The result or observation value is outside the reference range or expected norm (as defined for the ...
NNormal
The result or observation value is within the reference range or expected norm (as defined for the r...
IIntermediate
Bacterial strain inhibited in vitro by a concentration of an antimicrobial agent that is associated ...
MSmoderately susceptible
The patient is considered as carrier based on the testing results. A carrier is an individual who ca...
NCLNo CLSI defined breakpoint
Use when not enough clinical trial data published by the Clinical and Laboratory Standards Institute...
NSNon-susceptible
A category used for isolates for which only a susceptible interpretive criterion has been designated...
RResistant
Bacterial strain inhibited in vitro by a concentration of an antimicrobial agent that is associated ...
SSusceptible
Bacterial strain inhibited by in vitro concentration of an antimicrobial agent that is associated wi...
VSvery susceptible
The patient is considered as carrier based on the testing results. A carrier is an individual who ca...
AACritical abnormal
The result or observation value is outside a reference range or expected norm at a level at which im...
HHigh
The result for a quantitative observation is above the upper limit of the reference range (as define...
LLow
The result for a quantitative observation is below the lower limit of the reference range (as define...
HHCritical high
The result for a quantitative observation is above a reference level at which immediate action shoul...
LLCritical low
The result for a quantitative observation is below a reference level at which immediate action shoul...
HXabove high threshold
The observation/test result is interpreted as being outside the inclusion range for a particular pro...
LXbelow low threshold
The numeric observation/test result is interpreted as being below the low threshold value for a part...
H>Significantly high
A test result that is significantly higher than the reference (normal) or therapeutic interval, but ...
HUSignificantly high
A test result that is significantly higher than the reference (normal) or therapeutic interval, but ...
EEquivocal
The test or procedure was successfully performed, but the results are borderline and can neither be ...
L<Significantly low
A test result that is significantly lower than the reference (normal) or therapeutic interval, but h...
LUSignificantly low
A test result that is significantly lower than the reference (normal) or therapeutic interval, but h...
NDNot detected
The presence of the specified component / analyte, organism or clinical sign could not be determined...
INDIndeterminate
The specified component / analyte, organism or clinical sign could neither be declared positive / ne...
NEGNegative
An absence finding of the specified component / analyte, organism or clinical sign based on the esta...
POSPositive
A presence finding of the specified component / analyte, organism or clinical sign based on the esta...
EXPExpected
This result has been evaluated in light of known contraindicators. Once those contraindicators have ...
UNEUnexpected
This result has been evaluated in light of known contraindicators. Once those contraindicators have ...
DETDetected
The measurement of the specified component / analyte, organism or clinical sign above the limit of d...
SYN-RSynergy - resistant
A category for isolates where the bacteria (e.g. enterococci) are not susceptible in vitro to a comb...
NRNon-reactive
An absence finding used to indicate that the specified component / analyte did not react measurably ...
RRReactive
A presence finding used to indicate that the specified component / analyte reacted with the reagent ...
WRWeakly reactive
A weighted presence finding used to indicate that the specified component / analyte reacted with the...
SDDSusceptible-dose dependent
A category that includes isolates with antimicrobial agent minimum inhibitory concentrations (MICs) ...
SYN-SSynergy - susceptible
A category for isolates where the bacteria (e.g. enterococci) are susceptible in vitro to a combinat...